The Carlo Gavazzi WM15 energy analsyer can be installed in any switchboard to control energy consumption, main electrical variables and harmonic distortion.

Features:

  • Enhanced readability. The backlit graphical display allows the size of the digits to be adapted to the displayed variable. The instantaneous values of the current are also shown by a bar graph to have the plant situation at a glance.
  • Easy navigation. The setup and navigation of the pages are very intuitive thanks to the user interface with 4 mechanical push buttons. In addition, the slideshow function automatically displays the desired measurements in sequence without having to use the keypad.
  • Quick setup. Wizard and wiring correction on first startup, UCS mobile app for setup via OptoProg and optical port are some of the advantages allowing a quick, guided and errorless installations and commissioning. UCS software is available for free download.
  • Accurate measurement. It is compliant with the international accuracy standard IEC/EN62053-21, and the IEC/EN61557-12 performance requirements (active power and active energy). Optional high accuracy version: class 0.5S kWh according to IEC/EN62053-22.
  • Fiscal metrology. WM15 configuration access can be locked and terminals can be sealed in case of a MID certified model for fiscal metering.
  • Installation flexibility. WM15 is suitable for single-phase, two-phase, three-phase and wild-leg systems with different voltage levels and grid frequencies used worldwide.
  • Multi-language. Chinese and Korean versions are available as alternative to the standard English user interface

Specification

General

  • Material Housing: PC/ABS (UL94 V1)
  • Transparent cover: PC (UL94 V2)
  • Protection degree Front: IP51
  • Terminals: IP20
  • Terminals Screw fixed terminal block, min:0.05; max: 2.5 mm2
  • Overvoltage category Cat. III
  • Pollution degree 2
  • Mounting Panel 96 x 96
  • Weight 280 g

Electrical system

  • Managed electrical system
  • Single-phase (2-wire)
  • Two-phase (3-wire)
  • Three-phase with neutral (4-wire)
  • Three-phase without neutral (3-wire)
  • Wild leg system (three-phase, four-wire delta)
  • MID managed electrical system Three-phase with neutral (4-wire)
  • Three-phase without neutral (3-wire) (ARON)
  • Voltage inputs - MID
  • Voltage connection Direct
  • Rated voltage L-N 230 V
  • Rated voltage L-L 400 V
  • Voltage tolerance From 0.8 to 1.15 Un
  • Overload Continuous: 1.5 Un max
  • Input impedance Refer to “Power supply”
  • Frequency 50 Hz

Current inputs

  • Current connection Via CT
  • CT transformation ratio 2000 max
  • Rated current (In) 5 A
  • Minimum current (lmin) 0.05 A
  • Maximum current (lmax) 6 A
  • Start-up current (lst) 10 mA
  • Overload For 500 ms: 20 Imax (120 A)
  • Input impedance < 0.2 VA
  • Crest factor 3
  • Measurement type by means of internal shunts non mutually insulated (AV5 3X)
  • by means of internal CT (AV5 3H)

Downloads

Ask an expert about the
Carlo Gavazzi WM15 Power analyzer - MID approved with Modbus RS485 & Pulse (WM1596AV53XOSPFB)

Help & Advice

Knowledge Base

Knowledge Base

Our Knowledge Base section provides in-depth guides on metering related topics, and can aid you in the process of buying the right product.

Find out more

Our Products

addressarrow-leftcaret-downcaret-leftcaret-rightmenuorderpadlockpdf