The Crompton Instruments Integra 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and display of all electrical parameters including total harmonic distortion (THD) and individual, up to the 63rd harmonic. This version is auxiliary powered.
Nominal input voltage | 100-276V AC L-N (173–480V L-L) 600V MAX |
Max. continuous input overload voltage | 125% of nominal |
Max. short duration input voltage | 2 x nominal voltage for 1 second |
Nominal input voltage burden | < 0.2VA per phase |
Nominal input current | 1A AC or 5A A |
Nom. Input current burden | < 0.1 VA |
Max. continuous input overload current | 120% of nominal |
Max. short duration input current (300 msec) | 20 x nominal current for 1 second |
Operating range | Self Powered (From any of the three phases) |
Supply burden | 10 VA |
Voltage (V) | +/- 0.5% of range maximum |
Current (A) | +/- 0.5% of range maximum |
Frequency (Hz) | +/- 0.2% of mid-frequency |
Power factor (PF) | +/- 1% of unity (0.01) |
Active power (W) | +/- 1.0% of range maximum |
Reactive power (VAr) | +/- 1.0% of range maximum |
Apparent power (VA) | +/- 1.0% of range maximum |
Active energy (kWh) | +/- 1.0% of range maximum to IEC 62053-21 |
Reactive energy (kVArh) | +/- 1.0% of range maximum to IEC 62053-24 |
THD | 2% to 63rd harmonic |
Voltage (V) | 5 – 120% of nominal (Min 100V – self powered) |
Current (A) | 5 – 120% of nominal |
Frequency (Hz) | 44 – 66 Hz |
Power (W, VAr, VA) | 5 – 144% of nominal (bi-directional) |
Energy | 8 digit, upto 9999999.9 MWh. |
Power factor | 4 quadrant |
THD | 0 – 40% upto 63rd harmonic |
Operating Temperature | -25˚C to +55˚C |
Storage Temperature | -40˚C to +70˚C |
Relative Humidity | 0 to 95%, non-condensing |
Shock | 30g in 3 planes |
Vibration | 10Hz to 50Hz, IEC 60068-2-6, 2g |
Dielectric Voltage | 4kV between voltage and current to earth |
Attitude | 3000m |
Warm-up | 1 minute |
Pulsed output relay (configurable) | Opto-coupled, potential-free SPST-NO contact |
Contact Rating current | 2-27mA at 27V DC |
Contact Rating voltage | 5-27V DC |
Pulse Width | 60 / 100 / 200 ms |
Pulse rate | 0.01 / 0.1 / 1 / 10 / 100 kWh/kVArh |
Pulsed output relay (non-configurable | 3200IMP/kWh |
Communications | Modbus RTU (RS485) |
Type | 2-wire half-duplex |
Baud Rate | 4800, 9600, 19200, 38400 |
Address | 1 to 247 |
Enclosure Style | DIN 96 panel Moun |
Dimensions | 96 x 96 x 62mm |
Panel cut-out | 92 x 92mm |
Panel thickness | 1-5 mm |
Protection rating | Front IP54, Rear IP30 |
Material | UL 94-VO |
Weight | 340 g |
Cable Size | 0.05mm-4mm stranded wire |
Terminals | Voltage: Shrouded screw-clamp. Current: Screw |
Our Knowledge Base section provides in-depth guides on metering related topics, and can aid you in the process of buying the right product.
Find out moreOur in-house product experts are at hand to help you find the right products and solutions for your projects.
01423 340 000 Start live chat